Electrical. How Close To An Electrical Outlet Can A Pool Be? From http://www.swimmingpoolsteve.com/pages/installation-tips.html - Learn about the electrical requirements for a new swimming pool and the pool equipment. If a lot is less than eighty in width, the pool can be setback five feet from the property lines. 680.23 Wet-niche luminaires that are installed in the foot well of a spa are only required to reach the bench area when removed for maintenance. Bonding. PERMITS & INSPECTIONS: Tasks #1 and #4, are fairly straight forward for a licensed electrician, and require just a few hours to complete. Pool Barrier Requirements All outdoor pools, spas and hot tubs must be protected with a barrier (fence) that meets the requirements of the International Swimming Pool and Spa Code, Section 305 . The following will be verified: *Proper materials approved for pool installations have been used. (a) Structural Reinforcing Steel. 47_47 said: I would run a dedicated 40 amp circuit from the house directly to the hot tub and put in a sub panel in the pool house. . PVC conduit system is required outside. This pump as displayed in the video at the top of the page was able to move 82 gallons per minute of water while consuming 2.24 kW of power, running at full speed 3450 RPM. Installing an inground swimming pool will allow you to spend time. In fact, you will likely need a few permits. On the other hand, hot tubs need a lot of electricity. For additional information download the requirements for outdoor residential swimming pools pamphlet (PDF). Run a number 8 copper wire, a grounding ring, around the outside of the pool, 4 to 6 inches below ground level and 18 to 24 inches from the edges of the pool. A swimming pool barrier may be placed anywhere up to the property line, provided a local ordinance does not say otherwise, and as long as the pool is completely surrounded. However, with proper maintenance, some models. The electric motors, controllers, and wiring for pool covers shall be located not less than 5 feet (1524 mm) from the inside wall of the pool except where separated from the pool by a wall, cover, or other permanent barrier. Page 2 ABOVE GROUND PRIOR APPROVALS REQUIRED BEFORE SUBMITTING TO BUILDING DEPARTMENT: Zoning (908-735-8800 ext. Pool & Spa Depot has been installing above ground pools and semi- inground pools for over 20 years. These connectors must be listed for their use. As written, the barrier must be independent of any neighboring barrier and neighboring barriers are not to be shared for purposes of meeting pool barrier requirements. Does your swimming pool have any other electrical needs? Assume a jacuzzzi or hot tub portion with it? Grounding prevents shock through faults in an electrical system, while bonding prevents shock through differential currents running through the pools metallic components. 680.26(B) 4 Point bonding is not required to the vertical uprights of pools. Currently it looks like #10 bare solid bond wire was used between pool, screen enclosure, filter pump and spa pump back when pool was installed in 1997. The disconnect must be installed within sight of the pool or spa but can be no closer than 5 feet from the pool or spa so that you cannot turn the power on or off while leaning out of the water. The pool steel frame, light, ladders, deck rebar, pumps, and heat pump are all connected to a #8 bond wire. Electrician will also be required to bond all equipment Thanks in advance. Outlet receptacles within 20 feet of a pool or spa. Electric pool heaters use electricity to heat the heating element (usually metal coils). Slides. The Code requirements, if carefully followed, will reduce the electric shock hazards to an acceptable level. Use large enough conduit for the sub panel run. Make sure that your recreation areas in Long Island, NY, are a safe place by ensuring that you get a job well done. Should there also be a natural gas line to the service area for it. This gravel base locks the pool debris together and provides a firm, solid foundation for the soil. ), or a pool, spa, or hot tub constructed on or above the ground, with nonmetallic, molded polymeric walls or inflatable fabric walls regardless of dimension. Placement will be the same as pools Electrical Requirements The only electrical requirements to a storable above ground pool are as follows: If electric is Because of the massive amount of power that your above-ground pool pump is likely to pull, you may need to institute a circuit breaker upgrade. Now, all electrical outlets must be at least 6 feet from the inside of the wall and must be GFCI protected. The clean gravel is added in 1 foot level layers, firmly compacting each layer before adding another. structure is above grade, such as an aboveground pool, the barrier may be at ground level, such as the pool structure, or mounted on top of the pool structure. Do a load calculation for the size of the sub. A permit is required for all swimming and bathing pools which the water depth equals or exceeds 24" or the Electrical Permit Application (472.72 Kb) Download PDF file. 4170 New Jersey 42 | Blackwood, NJ 08012 The building permit will not be issued until the electrical permit has been applied for. Pools and decks may not be constructed over septic or wastewater systems or their repair area. What are the grounding requirements for the pool and equipment? Electrical bonding of the motors to the pool frame, metal ladders, metal within 5 feet of the pool wall, and related pool equipment shall be #8 solid copper minimum. There are some different types but again, the same principles apply. 1) Pool Pump Receptacle (Outlet) and Wiring Method a. 680.22 Electrical equipment other than receptacles and lighting must be a minimum of five feet away fromthe swimming pool unless separated by a barrier. You may want to be able to switch some lights from your main house out by the pool. Step 3. Bonding (connecting) of metal is typically done by a 8 gauge copper wire. Here are some factors that must be considered to properly determine the circuit wiring for a pool pump and pool equipment: Will there be one circuit or more circuits. NEC bonding requirements apply to in ground and above ground pools, and includes all metal components, equipment and the water itself. Pools are permitted in the rear and side yard of a lot. If you need to know the electrical requirements for your inground pool, here is a list of common pool equipment and the approximate volts and amps required for each: Pool Pump: 240v, 10amps Salt Water Chlorinator: 240v, approx 5-8 amps In Tennessee, barriers around private swimming pools must have access gates at least 48 inches tall and equipped with locking devices. You can control and automate your pool equipment from the panel or from a remote panel/control. An electric pool heater is just the generic term for any pool that uses an electric heating element to heat your pool. Pedestrian access gates must be self-closing, have a self-latching device at least 54 inches above the ground and open outwards from the pool. Expect to pay $1000 or more. Bonding the metal components of the pool and 4). 230 or 115? UTILITIES REQUIRED Water- for construction and filling of pool Electrical- temporary supply during construction and a The 2008 NEC added a requirement for pool motors to have GFCI protection whenever theyre rated 120V or 240V, 15A or 20A. Both grounding and bonding together prevent shock-related injuries and electrocution. The pumps and heat pump are connected to a 100 subpanel that is outside. 2) Soil Movement Application Application with pool plans and drainage calculations (if needed) $75 Application fee and $1,500 Escrow fee for Engineering review and inspections. PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the basic information needed to apply for a swimming pool permit to construct most private in-ground swimming pools. 3. This receptacle shall be ground fault protected and shall employ an InU se cover. Lights are small water features; thus, they dont have a lot of electrical needs. The electric motors, controllers, and wiring for pool covers shall be located not less than 5 feet (1524 mm) from the inside wall of the pool except where separated from the pool by a wall, cover, or other permanent barrier. Often the same circuit is used to power a GFCI electrical outlet underneath the pool sub panel. Most of us are aware that the pool must be bonded, but since 2008 the National Electrical Code (NEC) has mandated that pool water shall be electrically bonded, not just metals in the structure of the pool itself. 2) Soil Movement Application Application with pool plans and drainage calculations (if needed) $75 Application fee and $1,500 Escrow fee for Engineering review and inspections. 256) Health Department (908-788-1351) (if septic and well) BUILDING DEPARTMENT FORMS FOR PERMIT APPLICATION: Building Electrical Manufacturers specifications of pool and accessories: filters,. Mechanical Permit Application (450.69 Kb) Swimming Pool Gates. A designated circuit breaker panel is an absolute must on your pool. The setback for pools and all associated equipment (i.e., filters and decking) is ten feet. Both are needed to provide safety for anyone entering your pool. Ask an Electrician Online. Pools require plumbing and electrical work, and each of those requires separate permits. Pool Requirements cont. Inground pools usually cost between twenty-five and thirty-five thousand dollars. The very reason the original GFCI circuit breaker tripped indicates that there is something wrong with the circuit, and the GFCI circuit breaker was providing the protection against a potential electric shock. The Easytouch panel is a subpanel for breakers, relay center, low voltage transformer for the valve actuators, power source for the salt water generator and a computer. It would be best if you also examined the tile along the waterline for cracks and chips. located at a minimum of 6 feet from pool wall. Call the City of Ottawa at 3-1-1 for street lighting locates, which may run alongside or at the back of your property. Building permitfor pool and barrier. to the pool reinforcing steel or copper conductor grid at a minimum of four (4) points uniformly spaced around the perimeter of the pool. 680.23 Wet-niche luminaires that are installed in the foot well of a spa are only required to reach the bench area when removed for maintenance. Contact zoning staff at 919-996-2492 or currentplanning@raleighnc.gov to discuss the specifics of your in-ground pool project and general zoning standards relating to walls and/or fences before you begin. which will include the bonding requirements for the pool and/or spa. 680.22 Electrical equipment other than receptacles and lighting must be a minimum of five feet away fromthe swimming pool unless separated by a barrier. code requirements that are both directly and indirectly associated with your swimming pool. No pool shall be installed within 27, measured diagonally, from high voltage feeder wire (service entrance cable or utility supply lines). From memory I thought #8 solid was required for code. Most equipment that requires electricity must be protected by GFCI devices. Public spas must have an emergency disconnect that is visible and at least 5 feet from the spa, but this rule does not apply to single-family dwellings. The connections of metal by the copper wire allow for electric flow to pass through metal. The electrical equipment for swimming pools must be grounded and connected by wiring methods in accordance with the NFPA 70 National Electric Code (NEC). In the case of a pool pump breaker size, a 20-amp CB is the best choice to safely support a 240V/ 10-amp (usual setup for pool pumps) electrical system. This includes the following: Underwater pool lights greater than 15 volts. Reach out to our professional pool electrician and request more information about our inground pool electrical wiring services. I came here hoping for an expert view to sort through the disagreement. minimum #8 AWG copper wire (ground ring) must be installed. Section 4207 Covers above ground or temporary pool requirements. Pool loans exist for individuals who dont have the immediate cash for an installation. EASY-TO-USE: Intuitive front control panel provides easy operation, service and maintenance. Underground Electrical Inspection After grounding, bonding and all underground Electrical work is completed, the Electrical work shall be inspected before covering. 20 Ampere locking type receptacle required for filter motor for above ground pools. These are often easy to spot by the yellow Test button, and are usually 20 amp breakers. Openings in the fence must not permit the passage of a 4-inch diameter sphere. Requirements for GFCI protection. Pool, hot tub and water feature permit application forms include: Download PDF file. Also, check the grout between the tiles to make sure the tile is entirely surrounded and hasnt deteriorated with use. Phone: 847-564-4910 info@northshorepool.com; Store Hours: Monday Friday: 8:00am to 4:00pm Originally, outlets that supplied power to the circulation system of the pool had to be located further than 10 feet away from the inside of the wall without needing to provide ground fault protection. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4 inches (102 mm). Switches and sockets are not permitted. Overhead power lines as well as underground wiring represent a shock hazard when in close proximity to swimming pools. That means that the wires coming to the pool light J-box must come from a GFCI breaker. One is so you can know what size breaker is needed at the electric box and the other so you know what size of wire to run to the pools pump. Building Electric Plumbing Fire REQUIREMENTS FOR ABOVE GROUND POOL Electrical safety around swimming pools is critical. Zone 1 is the volume outside the first zone, extending to 2m from the pool edge and 2.5m in height. - No overhead electrical conductors should be installed within 15 feet of the pool. After crushing and tamping down the debris, gravel is added to the pool cavity, as shown above. Studente. Electric motors installed below grade level shall be of the totally enclosed type. Hydro Ottawa regulates minimum clearances for above grade electrical conductors adjacent to and over pools. Typically, residential homes have service panels in the range of 200-amp to 400-amp capacity. One of these measures is the bonding together of conductive portions of the pool and metal parts of electrical equipment associated with the pool. II. For nonconductive pool shells, bonding at four points shall not be required. The installation process for a semi- inground pool is only a 1-3 day process. Building Electric Plumbing Fire REQUIREMENTS FOR ABOVE GROUND POOL than 10 but not further than 20 from the outside pool wall (Can be existing and/or wired with any approved wiring method) I. Securing the electrical Permit, 2). The 2011 revision changed 680.21(C) to include 208V by replacing the or with through. The requirements have also been relocated to 680.21 from 680.22 (subsections in 680.22 renumbered accordingly).